  1. 01Why must dead tests be carried out with the installation isolated?
    • ATo ensure the RCD does not trip during the test
    • BTo allow the cables to cool to ambient temperature
    • CTo prevent electric shock and equipment damage
    • DTo reduce the prospective fault current at the board

    Why: Isolation prevents electric shock to personnel and protects test instruments, which apply their own test voltage, from damage by the supply.

  2. 02What is the correct sequence for safe isolation?
    • AProve dead with the tester first, then identify the circuit, isolate it and secure the isolation
    • BIdentify, isolate, prove dead, then secure the isolation once the circuit is confirmed dead
    • CIdentify, isolate, secure the isolation, then prove dead with a tester proved before and after
    • DIsolate the supply, prove dead, start work, then secure the isolation before leaving site

    Why: Regulation 462.1 requires the means of isolation to allow the full sequence: identify the supply, isolate it, SECURE IT AGAINST RE-CONNECTION, then prove dead. Securing comes BEFORE proving dead — lock off after testing and the circuit can be re-energised in the gap between the two, which is the exact scenario the procedure exists to prevent. The voltage indicator is proved on a known source before AND after the test, so a tester that failed mid-check cannot read as a dead circuit.

  3. 03When proving dead, the voltage indicator should be tested:
    • AOnce immediately before use
    • BBefore and after use
    • COnce after use only
    • DOnly if it appears faulty

    Why: Voltage indicators must be proven on a known live source before and after use.

Common questions

Is the Safe Isolation mock exam free?

Yes — 100% free, no sign-up needed. Questions are pulled at random from a substantial bank, with a worked explanation on every question after you submit.

Can I retake the mock exam?

Yes. Every attempt picks a different random selection and reshuffles the options, so each retake gives you genuinely new questions. No limit on retakes.

Does this count towards the real qualification?

No — this is independent practice material. To gain the actual qualification you need to sit the official assessment through an approved provider.

Certificate types
19Certificate types
Calculators
70+Calculators
Training courses
46+Training courses
AI specialists
8AI specialists

2,190+ electricians and apprentices · from £6.99 a month

We use cookies to improve the app and measure what works. Cookie Policy