Safe Isolation — 18th Edition (BS 7671) Practice
Free topic-focused mock exam: all 10 questions on Safe Isolation, drawn from the wider 18th Edition (BS 7671) bank. 60-minute timer, 70% to pass, worked explanation on every question. Use this when you've taken the full mock once and want to drill the topics you got wrong.
- Questions
- 10
- Time limit
- 60 min
- Pass mark
- 70% · 7/10
- Question bank
- 10
Free, no sign-up. Retake as many times as you like — the questions are reshuffled, with the answer order changed.
Sample questions
01Why must dead tests be carried out with the installation isolated?
- ATo ensure the RCD does not trip during the test
- BTo allow the cables to cool to ambient temperature
- CTo prevent electric shock and equipment damage
- DTo reduce the prospective fault current at the board
Why: Isolation prevents electric shock to personnel and protects test instruments, which apply their own test voltage, from damage by the supply.
02What is the correct sequence for safe isolation?
- AProve dead with the tester first, then identify the circuit, isolate it and secure the isolation
- BIdentify, isolate, prove dead, then secure the isolation once the circuit is confirmed dead
- CIdentify, isolate, secure the isolation, then prove dead with a tester proved before and after
- DIsolate the supply, prove dead, start work, then secure the isolation before leaving site
Why: Regulation 462.1 requires the means of isolation to allow the full sequence: identify the supply, isolate it, SECURE IT AGAINST RE-CONNECTION, then prove dead. Securing comes BEFORE proving dead — lock off after testing and the circuit can be re-energised in the gap between the two, which is the exact scenario the procedure exists to prevent. The voltage indicator is proved on a known source before AND after the test, so a tester that failed mid-check cannot read as a dead circuit.
03When proving dead, the voltage indicator should be tested:
- AOnce immediately before use
- BBefore and after use
- COnce after use only
- DOnly if it appears faulty
Why: Voltage indicators must be proven on a known live source before and after use.
Common questions
Is the Safe Isolation mock exam free?
Yes — 100% free, no sign-up needed. Questions are pulled at random from a substantial bank, with a worked explanation on every question after you submit.
Can I retake the mock exam?
Yes. Every attempt picks a different random selection and reshuffles the options, so each retake gives you genuinely new questions. No limit on retakes.
Does this count towards the real qualification?
No — this is independent practice material. To gain the actual qualification you need to sit the official assessment through an approved provider.