Free mock exam

Special Locations — 18th Edition (BS 7671) Practice

Free topic-focused mock exam: all 8 questions on Special Locations, drawn from the wider 18th Edition (BS 7671) bank. 60-minute timer, 70% to pass, worked explanation on every question. Use this when you've taken the full mock once and want to drill the topics you got wrong.

Questions
8
Time limit
60 min
Pass mark
70% · 6/8
Question bank
8

Free, no sign-up. Retake as many times as you like — the questions are reshuffled, with the answer order changed.

Sample questions

  1. 01What is the required IP rating for equipment in bathroom Zone 1?
    • AIPX6
    • BIPX5
    • CIPX4
    • DIPX7

    Why: Equipment in bathroom Zone 1 requires a minimum IP rating of IPX4.

  2. 02In zone 0 of a swimming pool, which protective measure is permitted?
    • ASELV at not more than 25 V AC RMS or 60 V ripple-free DC, the source being outside zones 0 and 1
    • BElectrical separation supplied by an isolating transformer mounted within zone 2 of the pool
    • CAutomatic disconnection of supply with a 30 mA RCD and supplementary bonding throughout
    • DSELV at not more than 12 V AC RMS or 30 V ripple-free DC, the source being outside zones 0, 1 and 2

    Why: Regulation 702.410.3.4.1 states that, except for fountains, in zone 0 only protection by SELV at a nominal voltage not exceeding 12 V AC RMS or 30 V ripple-free DC is permitted, with the SELV source installed outside zones 0, 1 and 2.

  3. 03In zone 1 of a swimming pool, what is the maximum SELV voltage permitted?
    • A25 V AC RMS or 60 V ripple-free DC, with the source installed outside zones 0, 1 and 2
    • B50 V AC RMS or 120 V ripple-free DC, the general SELV limit for dry locations
    • C12 V AC RMS or 30 V ripple-free DC, matching the limit that applies in zone 0
    • D230 V, provided the circuit is protected by a 30 mA residual current device

    Why: Regulation 702.410.3.4.1 states that, except for fountains, in zone 1 only protection by SELV at a nominal voltage not exceeding 25 V AC RMS or 60 V ripple-free DC is permitted, with the source installed outside zones 0, 1 and 2.

Common questions

Is the Special Locations mock exam free?

Yes — 100% free, no sign-up needed. Questions are pulled at random from a substantial bank, with a worked explanation on every question after you submit.

Can I retake the mock exam?

Yes. Every attempt picks a different random selection and reshuffles the options, so each retake gives you genuinely new questions. No limit on retakes.

Does this count towards the real qualification?

No — this is independent practice material. To gain the actual qualification you need to sit the official assessment through an approved provider.

Certificate types
16Certificate types
Calculators
70+Calculators
Training courses
46+Training courses
AI specialists
8AI specialists

1,000+ electricians · From £6.99/mo after trial

We use cookies to improve the app and measure what works. Cookie Policy