Free mock exam

Special Locations — 18th Edition (BS 7671) Practice

Free topic-focused mock exam: all 18 questions on Special Locations, drawn from the wider 18th Edition (BS 7671) bank. 60-minute timer, 70% to pass, worked explanation on every question. Use this when you've taken the full mock once and want to drill the topics you got wrong.

Questions
18
Time limit
60 min
Pass mark
70% · 13/18
Question bank
18

Free, no sign-up. Retake as many times as you like — the questions are reshuffled, with the answer order changed.

Sample questions

  1. 01What is the required IP rating for equipment in bathroom Zone 1?
    • AIPX6
    • BIPX5
    • CIPX4
    • DIPX7

    Why: Equipment in bathroom Zone 1 requires a minimum IP rating of IPX4.

  2. 02In zone 0 of a swimming pool, which protective measure is permitted?
    • ASELV at not more than 25 V AC RMS or 60 V ripple-free DC, the source being outside zones 0 and 1
    • BElectrical separation supplied by an isolating transformer mounted within zone 2 of the pool
    • CAutomatic disconnection of supply with a 30 mA RCD and supplementary bonding throughout
    • DSELV at not more than 12 V AC RMS or 30 V ripple-free DC, the source being outside zones 0, 1 and 2

    Why: Regulation 702.410.3.4.1 states that, except for fountains, in zone 0 only protection by SELV at a nominal voltage not exceeding 12 V AC RMS or 30 V ripple-free DC is permitted, with the SELV source installed outside zones 0, 1 and 2.

  3. 03In zone 1 of a swimming pool, what is the maximum SELV voltage permitted?
    • A25 V AC RMS or 60 V ripple-free DC, with the source installed outside zones 0, 1 and 2
    • B50 V AC RMS or 120 V ripple-free DC, the general SELV limit for dry locations
    • C12 V AC RMS or 30 V ripple-free DC, matching the limit that applies in zone 0
    • D230 V, provided the circuit is protected by a 30 mA residual current device

    Why: Regulation 702.410.3.4.1 states that, except for fountains, in zone 1 only protection by SELV at a nominal voltage not exceeding 25 V AC RMS or 60 V ripple-free DC is permitted, with the source installed outside zones 0, 1 and 2.

Common questions

Is the Special Locations mock exam free?

Yes — 100% free, no sign-up needed. Questions are pulled at random from a substantial bank, with a worked explanation on every question after you submit.

Can I retake the mock exam?

Yes. Every attempt picks a different random selection and reshuffles the options, so each retake gives you genuinely new questions. No limit on retakes.

Does this count towards the real qualification?

No — this is independent practice material. To gain the actual qualification you need to sit the official assessment through an approved provider.

Certificate types
19Certificate types
Calculators
70+Calculators
Training courses
46+Training courses
AI specialists
8AI specialists

1,600+ electricians · From £6.99/mo after trial