Free topic drill: 30 random questions from a pool of 116 on BS 7671 Inspection & Testing, drawn from the wider AM2 Online Knowledge Test bank. 60-minute timer, 70% to pass, worked explanation on every question. Use this after you have sat the full AM2 Online Knowledge Test mock exam and want to drill the topics you got wrong.

Questions
30
Time limit
60 min
Pass mark
70% · 21/30
Question bank
116

Free, no sign-up. Retake as many times as you like: different questions each time.

Sample questions

  1. 01What is the correct sequence for initial verification tests?
    • AContinuity of protective conductors, insulation resistance, polarity, Zs, RCD
    • BInsulation resistance, continuity of protective conductors, RCD, polarity, then Zs
    • CRCD operation, Zs, polarity, continuity of protective conductors, insulation resistance
    • DZs, RCD operation, polarity, insulation resistance, continuity of protective conductors

    Why: Regulation 643.1 requires the dead tests in order before energising: continuity of protective conductors and ring conductors, then insulation resistance, then polarity. Live tests follow, Zs and then RCD operation. Insulation testing before continuity is the usual slip, but a 500 V test to earth only means something once the cpc is proven continuous.

  2. 02Which instrument is used to test the continuity of protective conductors?
    • ARCD tester
    • BEarth fault loop impedance tester
    • CInsulation resistance tester
    • DLow resistance ohmmeter

    Why: Continuity of protective conductors is measured with a low-resistance ohmmeter or the continuity range of an insulation and continuity tester. GN3 recommends a source of 4 V to 24 V, DC or AC, giving at least 200 mA. An insulation resistance tester applies 500 V and reads in megohms, so it cannot resolve the fractions of an ohm a cpc gives.

  3. 03What test voltage is used for insulation resistance testing on 230 V circuits?
    • A1000V DC
    • B500V DC
    • C230V AC
    • D250V DC

    Why: Table 64 sets 500 V DC for circuits up to and including 500 V, other than SELV and PELV, so a 230 V circuit is tested at 500 V DC. 250 V DC is the SELV and PELV row, or the reduced test after vulnerable equipment is connected (Regulation 643.3.3). The test is always DC, never the 230 V AC supply.

Common questions

Is the BS 7671 Inspection & Testing mock exam free?

Yes, it is free with no sign-up needed. Questions are pulled at random from a substantial bank, with a worked explanation on every question after you submit.

Can I retake the mock exam?

Yes. Every attempt picks a different random selection and reshuffles the options, so each retake gives you genuinely new questions. No limit on retakes.

Does this count as a qualification?

No. This is independent practice material and does not award a qualification, card or certificate. Where a subject has a formal qualification or card, you gain it through an approved provider.

Certificate types
19Certificate types
Calculators
70+Calculators
Training courses
46+Training courses
AI tools
20+AI tools